This message is for the use case when an implementation has detected a Platform Watchdog Timer
Expired
Severity: Error
Serviceable: No
Automatically notify Support: No
Alert Category: System - OS Timeout
SNMP Trap ID: 21
CIM Prefix: IMM CIM ID: 0039
User Action:
Complete the following steps until the problem is solved:
1. Reconfigure the watchdog timer to a higher value.
2. Make sure that the BMC Ethernet-over-USB interface is enabled.
3. Reinstall the RNDIS or cdc_ether device driver for the operating system.
4. Disable the watchdog timer.
5. Check the integrity of the installed operating system.
6. If problem persists, collect Service Data log.
7. Contact Lenovo Support.
• FQXSPBR4004I: Server timeouts set by user [arg1]: EnableOSWatchdog=[arg2],
OSWatchdogTimout=[arg3], EnableLoaderWatchdog=[arg4], LoaderTimeout=[arg5].
A user configures Server Timeouts
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: none
SNMP Trap ID:
CIM Prefix: IMM CIM ID: 0095
User Action:
Information only; no action is required.
• FQXSPBR4005I: Management Controller [arg1]: Configuration saved to a file by user [arg2].
A user saves a Management Controller configuration to a file.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: none
SNMP Trap ID:
CIM Prefix: IMM CIM ID: 0109
User Action:
Information only; no action is required.
• FQXSPBR4006I: Management Controller [arg1]: Configuration restoration from a file by user [arg2]
completed.
This message is for the use case where a user restores a Management Controller configuration from a file
and it completes.
Severity: Info
.
Chapter 2
XClarity Controller events
27