2. Change the DIMM configuration so that the Near Memory/Far Memory ratio meets firmware
requirements, then reboot the system.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0059I: Bank sparing performed on CPU [arg1] high bandwidth memory channel [arg2]
pseudo-channel [arg3].
Severity: Info
User Action:
Information only; no action is required.
• FQXSFMA0060I: Partial cache line sparing performed on CPU [arg1] high bandwidth memory
channel [arg2] pseudo-channel [arg3].
Severity: Info
User Action:
Information only; no action is required.
• FQXSFMA0061M: An uncorrected recoverable memory error occurred on CPU [arg1] high
bandwidth memory channel [arg2] pseudo-channel [arg3].
Severity: Error
User Action:
Complete the following steps:
1. Power off the system and remove A/C power.
2. Restore A/C power and power on the system.
3. Reset UEFI to factory default settings.
4. If the problem persists, collect Service Data logs, and contact Lenovo Support.
• FQXSFMA0062M: An uncorrectable memory error occurred on CPU [arg1] high bandwidth memory
channel [arg2] pseudo-channel [arg3].
Severity: Error
User Action:
Complete the following steps:
1. Power off the system and remove A/C power.
2. Restore A/C power and power on the system.
3. Reset UEFI to factory default settings.
4. If the problem persists, collect Service Data logs, and contact Lenovo Support
• FQXSFMA0063I: A correctable memory error handled by ADDDC on DIMM [arg1]. DIMM identifier
is [arg2].
Severity: Info
User Action:
Information only; no action is required.
• FQXSFMA0064M: DIMM [arg1] disabled due to memory module power failure. DIMM [arg2]
detected and good.
Severity: Warning
User Action:
.
181