Complete the following steps:
1. Power off the system and remove A/C power.
2. Check DIMM slots specified in the message. If DIMM installed but undetected, remove it and then
restore the A/C power and power on the system.
3. If all DIMMs detected or error persists after removing undetected DIMMs, reseat all the DIMMs in the
slots specified by the message and then restore the A/C power and power on the system.
4. If the problem persists or undetected DIMM needs to be replaced, collect Service Data logs and
contact Lenovo Support.
• FQXSFMA0065I: Multi-bit CE of DIMM [arg1] has been deasserted after performing post package
repair. DIMM identifier is [arg2].
Severity: Info
User Action:
Information only; no action is required.
• FQXSFMA0065M: Memory address parity error occurred on CPU [arg1] high bandwidth memory
channel [arg2] pseudo-channel [arg3].
Severity: Error
User Action:
Complete the following steps:
1. Power off the system and remove A/C power.
2. Restore A/C power and power on the system.
3. Check Lenovo Support site for an applicable service bulletin.
4. If the problem persists, collect Service Data logs, and contact Lenovo Support to have failure part
replacement.
• FQXSFMA0066M: Memory address parity error occurred on CPU [arg1] channel [arg2] with DIMM
[arg3].
Severity: Error
User Action:
Complete the following steps:
1. Power off the system and remove A/C power.
2. Reseat the DIMMs specified by the event message.
3. Restore A/C power and power on the system.
4. If the problem persists, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0067G: Errors per row counter threshold limit exceeded on DIMM [arg1] sub-channel
[arg2] Rank [arg3] DRAM [arg4], need to restart the system for DIMM Self-healing to attempt post
package repair (PPR), DIMM identifier is [arg5].
Severity: Warning
User Action:
Complete the following steps:
1. Restart the system to allow for DIMM Self-healing to attempt hard post package repair (PPR) and
confirm that event ID FQXSFMA0026I was recorded.
2. Run advance memory test using the XClarity Provisioning Manager. Click Diagnostics > Run
Diagnostics > Memory Test > Advanced Memory Test to repair the DIMM.