_ Electronic convection oven _ rev. 0 ________________________MODD. EKF 664 TC – EKF 711 TC – EKF 1064 TC

3.7 Electrical connection

3.7 Electrical connection
3.7 Electrical connection
3.7 Electrical connection
The appliance must be connected to the electrical mains according to current regulations.
Before making the connection, make sure of the following:
-
the voltage and frequency of the power supply system match the data on the "rating"
plate affixed to the side of the appliance;
-
the limiting valve and the system are able to take the appliance's load (see the "rating"
plate);
-
the power supply system has an adequate earth connection according to current
regulations;
-
an all-pole disconnect switch with a minimum gap between contacts for use in
overvoltage category III equipment (4000V) must be fitted between the appliance and
the mains in the fixed connection to the mains and must be sized to take the load and
comply with current regulations (e.g. thermal-magnetic circuit breaker);
-
the all-pole disconnect switch used for connection is easy to reach once the appliance is
installed;
-
the yellow/green earth wire must not be disconnected by the switch;
the yellow/green earth wire must not be disconnected by
the yellow/green earth wire must not be disconnected by
the yellow/green earth wire must not be disconnected by
The appliance must be connected to an earthing system, which must be duly checked to
-
ensure it is in proper working order according to current code. This connection must be
made using the appropriate terminal located on the back, marked with the symbol
The earth wire must have a cross-sectional area of at least 2.5mm².
-
the power supply, when the appliance is operating, must not deviate from the rated
voltage value by more than +/-10%;
-
make sure that, once the power cord is inserted in the terminal block, it does not come
into contact with any part of the appliance that gets hot.
-
if the power cord is damaged, it must be replaced by the manufacturer or an approved
if the power cord is damaged, it must be replaced by the manufacturer or an approved
if the power cord is damaged, it must be replaced by the manufacturer or an approved
if the power cord is damaged, it must be replaced by the manufacturer or an approved
technical service centre or other similarly qualified person, so as to avoid any risks.
technical service centre or other similarly qualified person, so as to avoid any
technical service centre or other similarly qualified person, so as to avoid any
technical service centre or other similarly qualified person, so as to avoid any
_________________________________________________________________________________________ page 9 _
EKF 1111 TC – EKF 1664 TC – EKF 2011 TC
the switch;
the switch;
the switch;
.
risks.
risks.
risks.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ekf 711 tcEkf 1064 tcEkf 1111 tcEkf 1664 tcEkf 2011 tc

Table of Contents