14
|
Configuration
Cooling/Heating masterhood
About Cooling/Heating masterhood
Installer and user reference guide
86
Result: The fan of the indoor unit that corresponds to the selected indoor unit
number starts operating.
A
a
b
b
c
B
a
d
b
b
c
A Heat pump system
B Heat recovery system
a Outdoor unit
b Indoor unit
c Remote controller
d BS unit
When multiple indoor units are connected to an outdoor unit, one of these units
(or a group of indoor units, in case of group control) needs to be set as Cooling/
Heating master. The other units/groups then become Cooling/Heating slaves, and
are restricted in their operation by the master (e.g. one outdoor unit does not
allow for one indoor unit to run in Cooling operation while another runs in Heating
operation).
When an indoor unit or group of indoor units is set as Cooling/Heating master, the
other indoor units automatically become its slaves. For instructions, see
Cooling/Heating
masterhood" [
Status icon
Cooling/Heating masterhood corresponds to the following status icon:
b
b
c
c
c
b
b
c
c
c
4
 87].
"To set
BRC1H82W+K+S