Wall Mounting To Conventional Or Pre-Cast Flues - Valor Black Beauty Slimline Installation And Owner's Manual

Live fuel effect gas fire
Table of Contents

Advertisement

The fireplace opening must be within the following dimensions:
1 The total height of the closure plate is 660mm and will accommodate a maximum
opening height of 650mm (This allows a 10mm overhang). Heights above
635mm (Inclusive of sealing tape) will leave the sealing tape and closure plate visible
above the appliance.
2 Any opening visible below the appliance may be closed in.

5.10.3 Wall mounting to conventional or pre-cast flues.

The wall opening must be within the following dimensions:
*
The total height of the closure plate is 660mm and will accommodate a maximum
opening height of 650mm (This allows a 10mm overhang). Heights above
635mm (Inclusive of sealing tape) will leave the sealing tape and closure plate visible
above the appliance.
The bottom of the appliance must be at least 100mm above the finished floor
covering (See figure 2). This requires the top of the opening to be at least 650mm
above the finished floor covering. Any opening visible below the appliance may be
closed in but the depth of the catchment space within the wall opening must be as
shown in figure 4.
©
GDC Group Ltd. JAN 2017
INSTALLER GUIDE
Width
Max.
432mm
Min.
305mm
Width
Max.
432mm
Min.
305mm
Height
610mm 1
Max.
550mm 2
Min.
Height
610mm *
Max.
Min.
334mm
Page 15