Horizontal Terminations - Flex Vent 4" x 6-7/8"

These venting systems, in combination with the CV40E/CB40E Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by Warnock
Hersey/ Intertek. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination
Locations" section.
Regency
Direct Vent (Flex) System Termination Kits include all the parts needed to install the CV40E/CB40E using a flexible vent.
®
FPI Kit # Length
Contains:
#946-513
2 Feet
1.
6-7/8" flexible outer liner (Kit length)
2.
4" flexible inner liner (Kit length)
3.
spring spacers
#946-515
4 Feet
4.
thimble
5.
AstroCap termination cap
6.
screws
#946-516
10 Feet
7.
tube of Mill Pac
8.
plated screws
9.
S.S. screws #8 x 1-1/2" drill point
Notes:
1. Liner sections should be continuous without any
joints or seams.
2. Only Flex pipe purchased from Regency
used for Flex installations
3. Horizontal vent must be supported every 3 feet.
4. Regency
Direct Vent System (Flex) is only
®
approved for horizontal terminations.
5. Flex system can only be used up to a maximum
continuous vent length of up to 10 feet. If longer
runs are required, rigid pipe must be used.