Operation
Changing the Password
The password is numeric and can have up to six digits . Entering six spaces deletes the password, which deactivates the password
function . This restores the device to its original setting (scale is not password-protected) .
Access the Setup menu (see Chapter 6 .7 .2 .1, page 25) .
t
Level 1 Level 2
Level 3
INPUT
| - - - PASSWD.
| - - - OLD PW
| - - -
| - - -
| - - -
| - - -
| - - -
| - - -
| - - -
NEW PW

6.7.2.7 Resetting the Scale: "RESET"

If required, you can restore the scale to its factory settings .
Note:
If you have activated the password function, this feature is password-protected .
Access the Setup menu (see Chapter 6 .7 .2 .1, page 25) .
t
Level 1
Level 2
Level 3
SETUP
| - - - GEN.SRV.
| - - - MEN.RES.
|- - -
|- - - o NO
28
EVO1S | SPO1S Operating Instructions
Press O / P, select INPUT, press !
t
Press O / P, select PASSWD., press !
t
When an old password is active, OLD PW appears briefly so that you can enter the old password .
y
This appears "_ _ _ _ _ _ ."
y
The first line flashes .
y
Make the following inputs:
t
− O / P keys: Selects numbers 0 to 9 .
− §: Go back to the previous number .
− !: Confirm entry or go to the next number .
Repeat to enter the remaining numbers .
t
If you make an incorrect entry, NOT OK appears . Press ! and reenter the old password .
y
When you make a correct entry, NEW PW appears briefly so that you can enter the new
y
password .
This appears "_ _ _ _ _ _ ."
y
The first line flashes .
y
Make the following inputs:
t
− O / P keys: Selects numbers 0 to 9 .
− §: Go back to the previous number .
− You can enter spaces to delete the number/password .
− !: Confirm entry or go to the next number .
Repeat to enter the remaining numbers .
t
The password has been changed .
y
Press § several times to exit the menu .
t
Level 4
Press O / P, select SETUP, press !
t
Press O / P, select GEN.SRV., press !
t
Press O / P, select MEN.RES., press !
t
Press O / P, select DEFAUL.
t
DEFAUL.
Press !, "o" appears
t
The factory settings are loaded
y
Press § several times to exit the menu