Section 7: Fuel & Propane System
All pilot lights, appliances and their igniters (see operating instructions) should
be turned off before refueling of motor fuel tanks and/or propane containers.
These can cause ignition of flammable vapors, which can lead to a fire or
explosion.
FAILURE TO COMPLY COULD RESULT IN FIRE, DEATH OR SERI-
OUS INJURY.
Use care when fueling your motor fuel tanks and/or propane containers. Make certain your
propane tank is properly fastened in place.

Installing Propane Cylinder(s)

Single Cylinder Mounted On A-Frame (if so equipped)
1.
Connect the 3/8" low pressure hose to the outlet of
the two stage regulator.
2.
Attach the regulator with the "Z" bracket on the cen-
ter of the front wall with the vent pointing down.
3.
Attach the protective plastic cover to the regulator.
4.
The regulator has a 90° elbow that directs the inlet
toward the trailer curbside.
5.
Place the cylinder on the bracket provided on the
A-frame and position it so the outlet of the cylinder
valve is pointed directly outward to the curbside wall.
Attach the 1/4" inverted flare x 24" Type 1 pigtail
6.
hose to the regulator inlet and the right hand swivel
nut to the cylinder valve.
7.
Secure the cylinder to the A-frame bracket using the bolts, nuts and washers provided.
Double Cylinder Mounted On A-Frame (if so equipped)
When a second cylinder is installed, a tee check valve
is used to replace the 90° elbow at the top of the regu-
lator and another 1/4" inverted flare x 24" Type 1 pig-
tail is added. The regulator stays in the original posi-
tion.Place the second cylinder on the A-frame bracket
so the cylinder valve is pointed to the roadside of the
recreation vehicle.
1.
Secure the second cylinder to the A-frame using
the bolts, nuts and washers provided.
2.
Attach the second 24" hose to the tee check valve
on the regulator and the right handed swivel nut
to the cylinder valve.
Located in a recessed compartment or housing (if so equipped)
1.
Connect the 3/8" low-pressure hose to the outlet of the two-stage regulator.
2.
Place the cylinder on the bracket in the recess compartment or housing and secure them
so the outlets of the cylinder valves are facing the "sidewalls" of the compartment or
housing (opposite of each other).
3.
Mount the regulator on the center back wall of the compartment or housing so the vent
is pointed downward.