™ NOTE: If the inlet filter is difficult to re-install, use a
small amount of soap on the O-rings. NEVER USE
GREASE as the O-rings are not resistant to grease.
When the drain chute is folded out, it protrudes past the sidewall of the
RV.
When walking past or stooping down, make sure you and others have
sufficient clearance to prevent injuries.
Never actuate the Easy Drain Lever as long as the appliance is under
water pressure or is still hot.
Never put fingers between the Easy Drain Lever and the latch.
Winterization
Freezing of the water heater and its plumbing components will result in severe damage not
covered by warranty. Follow these recommendations if the unit is to be stored in a freezing
environment for long periods of time. At the start of the winter season or before traveling to
a location where freezing conditions are likely, the unit must be winterized.
To winterize the Aqua Go water heater, drain the water out of the water heater
using the drain chute.
Set the RV plumbing bypass valves so no water or antifreeze will enter the water
heater.
Winterize the RV water lines with antifreeze as normal. (Refer to Winterinzing
the Plumbing System).
Do not insert the water inlet filter or heating cartridge into the appliance during
winter if the appliance is not used.
Close the EZ Drain Lever and the access door.
™ NOTE: Using air pressure to blow out the Aqua Go water heater is NOT
recommended and may damage the appliance.