Jayco NORTH POINT 2023 Owner's Manual page 125

Table of Contents

Advertisement

valve for winterizing. It is not affected by high altitudes.
The output temperature of the water depends on the temperature of the inlet water AND the
amount of hot water that is drawn. If the inlet water temperature is over 65 º F, the tankless
water heater will generate water in the range of 105°F to 120°F (on low flame) depending on
the water flow selected by the user.
Operating Tips
Purge air out of ALL hot and cold water lines.
Open the water heater door and turn the power switch "ON".
Set GMC (gas modulator dial) to appropriate setting.
Normal weather – set dial to the middle area.
Extreme cold weather – set dial to the extreme right (large flame).
Extreme hot weather – set dial to the extreme left (small flame).
Open hot water faucet to a medium water flow. It may take a few seconds for the
water to travel from the water heater to the faucet.
To reduce temperature:
Turn GMC dial "counter-clockwise".
Increase hot water flow.
Gradually add cold water.
To increase temperature:
Turn GMC dial "clockwise". NOTE: Use caution not to increase the dial
too much which could cause the hot water temperature to rise to the point
the water heater "limits' and turns OFF the flame (flame shut off is approxi-
mately 131° F).
Reduce hot water flow.
Refer to the manufacturer's manual for detailed operating and safety information.
Winterization
Freezing of the water heater and its plumbing components will result in severe damage not
covered by warranty Follow the recommendation(s) below if the unit is to be stored in a
freezing environment for a long period of time. At the start of the winter season or before
traveling to a location where freezing conditions are likely, the unit must be winterized.
The very small amount of water present in the heat exchanger DOES NOT require the in-
stallation of a bypass kit. Refer to the Winterization section for details.
Pressure - Temperature Relief Valve
Valve is not serviceable; if defective it must be replaced.
Tampering with valve will result in scalding injury. Do not place a plug
or reducing coupling on outlet part of valve. If you use a discharge line
allow complete drainage for both valve and line.
Tampering with valve will void the warranty.
THIS VALVE IS A SAFETY COMPONENT AND MUST NOT BE REMOVED FOR
ANY REASON OTHER THAN REPLACEMENT.
THE PRESSURE RELIEF VALVE SHOULD ONLY BE REPLACED BY A QUALI-
FIED SERVICE TECHNICIAN.
SCALDING INJURY-EXPLOSION
Table of Contents
Section 8: Plumbing System
119

Advertisement

Table of Contents
loading

Table of Contents