The hour setting is automatically selected; press the
Arrow buttons to increase or decrease the value. Press
the OK button to confirm the value and to advance to the
next entry. Enter the correct minutes and press the OK
button to save and return to the Main Menu.
Note:
Disable the AUTO STANDBY TIME by selecting
"- -" in "hours" settings.
Event History
The EVENT HISTORY screen will display up to 200
events. The most recent event is displayed on screen 1.
The data and time description is displayed on each
screen. Press Arrow buttons to display the next screen;
press the OK or C button to return to the main menu.
Listed below are the variable messages which will
appear, along with an explanation of the corrective
action.
DOOR O.—(DOOR OPEN) A product door is not in place
or it is loose.
FLU.LEV.—(ALARM—INSUFFICIENT FLUID LEVEL)
The fluid level is too low to operate; switch off the
machine. Call your Taylor service technician.
TEV INT.—(ALARM—PROBE TEV INTERRUPTED) The
hopper thermistor is open; switch off the machine. Call
your Taylor service technician.
TEV S.C.—(ALARM—PROBE TEV SHORT CIRC.) The
hopper thermistor has shorted; switch off the machine.
Call your Taylor service technician.
TEC INT.—(ALARM—PROBE TEC INTERRUPTED)
The barrel thermistor is open; switch off the machine.
Call your Taylor service technician.
TEC S.C.—(ALARM—PROBE TEC SHORT CIRC.) The
barrel thermistor has shorted; switch off the machine.
Call your Taylor service technician.
TEF INT.—(ALARM—PROBE TEF INTERRUPTED) The
fluid thermistor is open; switch off the machine. Call your
Taylor service technician.
User Interface
TEF S.C.—(ALARM—PROBE TEF SHORT CIRC.) The
fluid thermistor has shorted; switch off the machine. Call
your Taylor service technician.
CTS INT.—(ALARM—PROBE CTS INTERRUPTED)
The CTS thermistor is open; switch off the machine. Call
your Taylor service technician.
CTS S.C.—(ALARM—PROBE CTS SHORT CIRC.) The
CTS thermistor has shorted; switch off the machine. Call
your Taylor service technician.
THERMAL—(ALARM—THERMAL OVERLOAD) Press
the STOP button and wait 5 minutes for the machine to
cool. Restart in AUTO. If the alarm continues, call your
Taylor service technician.
PHASES—(ALARM—PHASES L2-L3 SWITCHED)
Press the STOP button and switch off the machine. Call
your Taylor service technician.
PHASES/N—(ALARM—SWITCH PHASE / NEUTRAL)
Press the STOP button and switch off the machine. Call
your Taylor service technician.
MICRO TA—(ALARM—NO CURRENT SIGNAL OR
DEFECTIVE TRANSFORMER) Press the STOP button
and switch off the machine. Call your Taylor service
technician.
DEV. KO—(ALARM—DEVICE KO!) Switch off the
machine. Call your Taylor service technician.
COM. KO—(ALARM—COMMUNICATION ERROR!)
Switch off the machine. Call your Taylor service
technician.
TIME OUT—(ALARM—BATCH TIME OUT) The
compressor run time exceeded the 120-minute timer.
Replace the scraper blades during the next brush
cleaning. If that does not resolve the fault, call your Taylor
service technician.
Model 0736
USER INTERFACE
5
5-7