USER INTERFACE
Lockout History
The LOCKOUT HISTORY screen displays a history of
the last 200 soft locks, hard locks and aborted Heat
cycles. The most recent lockout is displayed on screen 1.
The data and time description is displayed on each
screen. Press the Arrow buttons to display the next
screen; press OK or C button to return to the main menu.
The following variable messages which will appear, along
with an explanation of the corrective action:
Faults occurring while in Heat mode
LOCK HT—(HEAT MODE FAILURE) The maximum
allowable heat mode time exceeded 90 minutes.
LOCK CL—(COOL MODE FAILURE) The maximum
allowable cool mode time exceeded 120 minutes.
LOCK TT—(TOTAL TIME FAILURE) The maximum
allowable total heat treatment time exceeded 4 hours.
LOCK OP—(OPERATOR ABORT) The operator has
aborted the heat treatment cycle.
WARN. PS—(POWER FAIL IN H/C) A power failure
occurred during the heat treatment cycle.
5
WASHING REQUIRED—(BRUSH CLEAN TIMEOUT)
The total days in operation exceeded the brush clean
cycle setting.
Faults Occurring While in Auto mode
HP 5C 4H—The mix temperature in the hopper was
above 41°F (5°C) more than four hours.
BR 5C 4H—The mix temperature in the barrel was above
41°F (5°C) more than four hours.
HP 5C PF—The mix temperature in the hopper was
above 41°F (5°C) more than four hours following a power
failure.
BR 5C PF—The mix temperature in the barrel was above
41°F (5°C) more than four hours following a power
failure.
HP 7C 1H—The mix temperature in the hopper was
above 45°F (7°C) more than one hour.
BR 7C 1H—The mix temperature in the barrel was above
45°F (7°C) more than one hour.
HP 15C—The mix temperature in the hopper exceeded
59°F (15°C).
BR 15C—The mix temperature in the barrel exceeded
59°F (15°C).
5-8
Heat Cycle Summary
The HEAT CYCLE SUMMARY screen displays the hours
since the last Heat cycle, the hours since the product
temperature was above 150°F (65.6°C), and the number
of Heat cycles completed since the last brush-clean date.
Heat Cycle Data
The HEAT CYCLE DATA screen contains a record up to
400 Heat Treatments Cycles. The most recent Heat cycle
is displayed on screen 1. The data and time description is
displayed on each screen. Press Arrow buttons to display
the next screen; press C button to return to the main
menu.
Select the desired cycle and press the OK button to open
the detail screen. The screen displays the month and day
of the Heat cycle, the start time and end time. The middle
line indicates if an alarm or a lockout occurred during the
Heat cycle.
The remaining lines indicate the following:
HEAT—Total time for the hopper (H) and barrel (B) to
reach 150 °F (65.6°C).
OVER—Total time the hopper (H) and barrel (B)
temperature was above 150 °F (65.6°C).
Model 0736
Figure 5-12
Figure 5-13