Wiring Method - Omron F3SJ-B0185P25-01TS User Manual

Safety light curtain
Table of Contents

Advertisement

Wiring/Installation

Wiring Method

Perform wiring according to the following procedure.
1.
Connect an emitter cable (F39-JD-L, gray, sold separately) to the emitter's connection cable (gray).
2.
Connect a receiver cable (F39-JD-D, black, sold separately) to the receiver's connection cable
(black).
3.
Connect the 0 V line of the power supply directly to the protective earth (PE).
 Single-ended connector cable (F39-JDA, sold separately)
Set model
name
F39-JD3A
F39-JD7A
F39-JD10A
F39-JD15A
F39-JD20A
<Internal wiring diagram> (F39-JDA-L, F39-JDA-D)
Connected to connection cable or
double-ended connector cable
Twisted pair wires are white and red, brown and blue, black and yellow, and gray and pink
F3SJ-B
64
User's Manual
39.5
Insulated vinyl round cable dia. 6.6, shielded 8-wire (4-pair)
(Cross section of conductor: 0.3mm
M12 IP67 connector
Emitter cable
F39-JD3A-L
Gray cable
F39-JD7A-L
F39-JD10A-L
F39-JD15A-L
F39-JD20A-L
1
White
2
Brown
3
Black
1
2
4
Yellow
7
3
5
Gray
8
6
4
6
Pink
5
7
Blue
8
Red
Female
Shield
L
2
/insulator diameter: dia. 1.15mm)
Receiver cable
F39-JD3A-D
Black cable
F39-JD7A-D
F39-JD10A-D
F39-JD15A-D
F39-JD20A-D
Emitter
White
+24 VDC
Brown
Test input
Black
Reset input
Yellow
Communication line (+)
Gray
Pink
Communication line (-)
Blue
Red
(Unit: mm)
L (mm)
3000
7000
10000
15000
20000
Receiver
NC
Safety output 2
+24 VDC
Safety output 1
Auxiliary output
Communication line (+)
Communication line (-)
0V
0V
External device
NC
monitoring input
Shield

Advertisement

Table of Contents
loading

Table of Contents