Assembly
4.
Assembly
4.1.
Mounting position
4.2.
Handwheel fitting
4.3.
Actuator: mount to valve
12
AUMA actuators and actuator controls can be operated without restriction in any
mounting position.
Figure 6: Handwheel
[1]
Spacer
[2]
Input shaft
[3]
Handwheel
[4]
Circlip
1.
If required, fit spacer [1] onto input shaft [2].
2.
Slip handwheel [3] onto input shaft.
3.
Secure handwheel [3] using the circlip [4] supplied.
Danger of corrosion due to damage to paint finish and condensation!
→ Touch up damage to paint finish after work on the device.
→ After mounting, connect the device immediately to electrical mains to ensure
that heater minimises condensation.
The actuator is mounted to the valve using a coupling (standard) or via lever. Separate
instructions are available for actuator mounting to the valve when equipped with
base and lever.
SQ 05.2 – SQ 14.2/SQR 05.2 – SQR 14.2