Serial device server B configuration steps
Step 1 Log in to the Web configuration interface and select "Serial Server> COM Mode
Settings".
Step 2 Select "COM1" from the serial port number drop-down list box.
Step 3 Click the "Work Mode" drop-down list box and select "Pair Master Mode".
Step 4 Enter the IP address "192.168.1.254" of the serial device server A in the "Dest
Address" text box.
Step 5 Enter the listen port "30000" of the serial device server A in the "Dest Port" text box.
Step 6 Other parameters maintain the default, click "Submit".
After the completion of the above configuration, serial server A and serial server B
establish connection successfully, and they can send and receive serial data from
each other.

UDP Rang Mode

Background introduction
When the router, switch and other devices do not support multicast function, the
serial device server can work in the UDP Rang mode to achieve multicast function.
Assuming that the serial port COM1 of the serial device server is connected to the
host computer, it needs to transmit the serial data to two hosts that specify the same
network segment "192.168.1.61" to "192.168.1.62" through the UDP protocol at the
same time.
The parameters of the serial server (UDP server) are as follows:
IP Address: 192.168.1.250
Local Port: 30000