UDP Client Mode

Background introduction
Assuming that the serial port "COM1" of the serial server works in the "UDP client
mode", it initiates a connection with a host PC, and the host can read or send
Ethernet data to a serial device. Compared with TCP mode, UDP protocol is faster
and more efficient.
The parameters of the serial server (UDP client) are as follows:
IP Address: 192.168.1.250
Local Port: 30000
Baud rate: 115200
Parity bit: None
Data bit: 8
Stop bit: 1
Host PC (UDP server mode) parameter information as follow:
IP address: 192.168.1.61
Local Port:31000
Operation Steps
Step 1 Configure the IP address of the serial server.