TCP Client Mode
Background introduction
Assuming that the serial port "COM1" of the serial server is working in "TCP client
mode", it initiates a connection with a host PC, and the host can read or send
Ethernet data to a serial device.
When the data transfer is completed, the serial server will automatically shut down
the network connection after 30 seconds.
The parameters of the serial server (TCP client) are as follows:
IP Address: 192.168.1.250
Local Port: 30000
Baud rate: 115200
Parity bit: None
Data bit: 8
Stop bit: 1
Host PC (TCP server mode) parameter information as follow:
IP address: 192.168.1.61
3onedata proprietary and confidential
Copyright © 3onedata Co., Ltd.
NP Series Serial Server User Manual