UDP Server Mode

Background introduction
Assuming that the serial port "COM1" of the serial server is operating under "UDP
server mode", passively waiting for one host PC to connect, and the host can read or
send Ethernet data to a serial device. Compared with TCP mode, UDP protocol is
faster and more efficient.
The parameters of the serial server (UDP server) are as follows:
IP Address: 192.168.1.250
Local Port: 30000
Baud rate: 115200
Parity bit: None
Data bit: 8
Stop bit: 1
Host PC (UDP client mode) parameter information as follow:
IP address: 192.168.1.61
Local Port:31000
Operation Steps
Step 1 Configure the IP address of the serial server.