Floor Protector - Pacific energy ALDERLEA T4 LE Operating And Installation Instructions

Table of Contents

Advertisement

The stove may be installed on a combustible floor provided noncombustible ember protection is used.
This protection must extend as follows:
U.S.A. Only
Minimum Width - 34"(864mm)
Minimum Overall Depth - 35"(8 9 0mm)
3"
75mm
8"
203mm
16" [406mm]
Figure 2: T4 Floor protector - USA.
In Canada: 18" (457 mm) on
the firing side and 8" (203 mm)
to the other sides.
ALT 4-LE 040523-28

Floor Protector

Non-combustible
floor protector
8"
203mm
Minimum Width - 44"(1.120m)
Minimum Overall Depth - 45"(1.14 5 m)
8"
203mm
Non-combustible
floor protector
Figure 3: T4 Floor protector - CAN.
13
In USA: 16" (406 mm) to the front and
8" (203 mm) to the sides of the fuel
loading door opening. See Figure #2.
This protection is also required under
the chimney connector and 2" (51 mm)
beyond each side if using any horizontal
venting.
CANADA Only
8"
203mm
18" [460mm]
100003978
8"
203mm

Advertisement

Table of Contents
loading

This manual is also suitable for:

Alderlea t4 le classic

Table of Contents