Warning: Under no circumstances is this heater to be installed in a makeshift or "temporary" manner. It
may be fired only after the following conditions have been met.
DO NOT ATTEMPT TO CONNECT THIS HEATER TO ANY AIR DISTRIBUTION DUCT.
DO NOT INSTALL IN ANY FIREPLACE.
Outside combustion air or fresh air into the room may be required in your area, consult local building
codes (see Combustion Air section).

Chimney and Connector

The chimney system must be a ULC-S629 or UL-130HT listed Stainless chimney or a Masonry chimney
suitable for use with solid fuel, that is lined, in good condition and meets fire and building codes.
The chimney flue size should be the same as the stove outlet (6 inches) for optimal performance.
Reducing or increasing the flue size may adversely affect stove performance.
Chimney flue exit is to be 3 feet (1 m.) above roof and two feet (0.6 m) above highest projection within 10
feet (3 m).
The installation must meet all local codes.
Do not connect this unit to a chimney flue serving another appliance. Minimum system height is 15 feet
(4.6 m.) (measured from base of appliance).
BOTH CHIMNEY SYSTEM AND CONNECTOR MUST BE LISTED TO:
IN CANADA - ULC S-641 LISTED double wall connector and ULC-S629 LISTED CHIMNEY,
IN USA - UL-103 HT LISTED CONNECTOR AND CHIMNEY

When using a Double-Wall Connector

Use a listed double-wall connector.
If a listed chimney and double-wall connector are to be connected to the stove, install all components as
per the chimney/connector manufacturer's installation requirements.

When using a Single-Wall (smoke pipe) Connector

The single wall pipe section must be:
If you are using smoke pipe/chimney connector in conjunction with the listed chimney system, consult
local/national fire or building codes for connector installation. Follow the chimney manufacturer's
complete instructions for the installation of the chimney system.
As short and straight as possible, use six inch diameter, 24 gauge black pipe that is clean and in new
condition.
Installed with the crimped or male ends pointing down. (This will carry any liquid creosote or condensation
back into the stove) and secured at every joint and collar with 3 sheet metal screws.
The chimney connector shall not pass through an attic, roof space, closet or similar concealed space,
floor, or ceiling. Where passage through a wall, or partition of combustible material is desired, the installa-
tion shall conform to CAN/CSA-B365, Installation Code for Solid-Fuel-Burning Appliances and Equipment