Minimum Clearance to Combustibles
FIG. #2
375mm
527mm
527mm
250mm

Floor Protector

The stove may be installed on a combustible fl oor provided ember
protection made from a 6mm thick non-combustible material with
a thermal conductivity value of .4w/m degree K.
This protection must extend as follows:
(300 mm) on the fi ring side and 200mm both sides of the door
opening. See Figure #3 below.
8
Single Wall Connector
350mm
660mm
Single Wall Connector with Shield
350mm
660mm
776mm
250mm
706mm
200mm
FIG. #3
Minimum Width - 781mm
Minimum Overall Depth - 723mm
Minimum Thickness - 6mm
[300mm]
[200mm]
[781mm]
250mm
200mm
[723mm]
[200mm]
Non-combustible
Floor Protector
220514-20