Event Setup
Define various events, and specify the conditions to notify the user in various ways.
Alarm Out
\ \
Specify the alarm output conditions with the work schedule.
Alarm Out
From <SYSTEM SETUP> - <EVENT>, select
1.
<ALARM OUT>.
Use the [
/ENTER] buttons on the remote
▲▼ ◀▶
2.
control or use the mouse to select <ALARM OUT>
and configure the related settings.
NAME : You can rename the alarm.
i
OPERATION : Set the alarm output mode.
i
N/O (Normal Open) : It normally stays Open.
-
However, if an event occurs, it will switch to Close.
N/C (Normal Close) : It normally stays Close.
-
However, if an event occurs, it will switch to Open.
DURATION : Specify the duration of the alarm
i
output.
TRANSPARENT : Keep the alarm out for as much time as the event lasts.
-
UNTIL KEY : Keep the alarm out until a mouse or remote control button is pressed.
-
5 ~ 300 SEC : Keep the alarm out for as long as specified.
-
TEST : Forcibly output the alarm for the test purpose.
i
To apply the change, click <APPLY> in the bottom of the screen.
3.
When done, press the [EXIT] button on the remote control or click <CLOSE> in the lower screen. The confirmation
4.
message appears and you will return to the previous menu.