P4.Xxx Diagnosis Parameters - Delta ASDA-B3 Series User Manual

Hide thumbs Also See for ASDA-B3 Series:
Table of Contents

Advertisement

Parameters

P4.xxx Diagnosis parameters

P4.000
8
Default: 0x00000000
Format: HEX
Settings:
The last abnormal status record.
Low word (LXXXX): the alarm number.
High word (hYYYY): the error code corresponding to CANopen / DMCNET / EtherCAT.
For example, when the low word displays ALF21, the high word displays the error code of ALF21.
P4.001★
Default: 0x00000000
Format: HEX
Settings:
The second to last abnormal status record.
Refer to the description of high / low word in P4.000.
P4.002★
Default: 0x00000000
Format: HEX
Settings:
The third to last abnormal status record.
Refer to the description of high / low word in P4.000.
P4.003★
Default: 0x00000000
Format: HEX
Settings:
The fourth to last abnormal status record.
Refer to the description of high / low word in P4.000.
8-114
Fault record (last)
Unit: -
Fault record (second to the last)
Unit: -
Fault record (third to the last)
Unit: -
Fault record (fourth to the last)
Unit: -
Control mode: All
Setting range: -
Data size: 32-bit
Control mode: All
Setting range: -
Data size: 32-bit
Control mode: All
Setting range: -
Data size: 32-bit
Control mode: All
Setting range: -
Data size: 32-bit
ASDA-B3
Address: 0400H
0401H
Address: 0402H
0403H
Address: 0404H
0405H
Address: 0406H
0407H