ECF ASSEMBLY AND INSTALLATION INSTRUCTIONS
STEP ONE
Remove all contents from package and place on a
clean, flat surface. Inspect the shipment for any dam-
ages. If damages are found, immediately notify your
carrier and your Kasco Marine, Inc. representative.
Next, cross reference the parts included in the ship-
ment with the Parts Included sheet in this manual on
page 13. Make sure you have all the parts needed. If
any shortages are found, contact your Kasco repre-
sentative immediately.
STEP TWO
Position the Float (Part B1)upside down (lengthwise
channels facing up) and place the Base Strap (Part
B2) so the three holes in the Base Strap align with the
three threaded holes that comprise the lengthwise
midline of the Float.
STEP THREE
Position the Adjustment Bracket (Part B3) over the
two holes at the back end of the Float and Base Strap.
Loosely secure the Adjustment Bracket to the Float
using two 1/4" x 1/2" (Part B8) Stainless Steel Bolts
and two Stainless Steel Lock Washers (Part B13).
(See photo above for orientation.)
STEP FOUR
Place one of the three Angle Brackets (Part B4)
perpendicular to the Base Strap at the front end of the
Base Strap. One of the two center holes of the Angle
Bracket should be positioned over the hole in the
Base Strap and the threaded hole in the Float. Secure
the Angle Bracket to the Float using three 1/4" x 1/2"
Stainless Steel Bolts and three Stainless Steel Lock
Washers. (See photos in the next column for specific
instructions based on the size circulator purchased.)
Tighten all hardware at this time with the
7/16" (11mm)socket and wrench.
Models 2400 & 3400
- Angle posterior to
bolts.
STEP FIVE
With a felt-tip marker, draw three to four marks
around the circumference of the motor housing at the
appropriate measurement from the back (or bottom)
of the motor housing given
below:
2400: 3/4" (1.9cm)
3400: 3-3/8" (8.57cm)
8400: 5-1/2" (14 cm)
STEP SIX
Place the two U-Brackets (Part B6) directly across
O
from each other (180
) over the top ring of the motor
cage. The cord clamp on the cage should be 90
from each of the U-Brackets.
18
Model 8400 - Angle
anterior to bolts.
O

Advertisement