Download Print this page

Kasco F2400EAF Owner's Manual

50hz fountain, aerator, & circulator

Advertisement

Quick Links

I.
Safety Instructions .........................................................
II.
General Owner's Instructions & Unit Specs............................
III.
Quick Disconnect & Strain Relief Instructions.........................
IV.
Cord Sizing and Gland Selection ........................................
V.
EVFX & 2400EJF Parts Included, Tools Needed, & Pattern Sizes..
VI.
EVFX & 2400EJF Assembly Instructions...............................
VII.
8400EJF & 3.1EJF Parts Included, Tools Needed, & Pattern Sizes
VIII.
8400EJF & 3.1EJF Assembly Instructions..............................
IX.
EAF and ECF Parts Included & Tools Needed.........................
X.
EAF Assembly Instructions................................................
XI.
XII.
ECF Assembly & Installation Instructions..............................
XIII.
Maintenance Recommendations..........................................
XIV.
Troubleshooting Tips.......................................................
XV.
Contact Information.........................................................
Phone (715) 262-4488 * Fax (715) 262-4487
www.KascoMarine.com * sales@kascomarine.com
Making a Splash!
CONTENTS
Kasco Marine, Inc.
800 Deere Rd.
Prescott, WI 54021
2
3
4-5
5
6-7
8-9
10-11
12-13
14
15-16
17
18-20
21
22
23
Made in the USA
Rev. 1/23/08

Advertisement

loading

Summary of Contents for Kasco F2400EAF

  • Page 1: Table Of Contents

    XII. ECF Assembly & Installation Instructions………………………… 18-20 XIII. Maintenance Recommendations…………………………………… XIV. Troubleshooting Tips………………………………………………. Contact Information………………………………………………... Kasco Marine, Inc. 800 Deere Rd. Prescott, WI 54021 Made in the USA Phone (715) 262-4488 * Fax (715) 262-4487 www.KascoMarine.com * sales@kascomarine.com Rev. 1/23/08...
  • Page 2 We at Kasco Marine, Inc. would like to both thank and congratulate you on your purchase of a 50Hz Fountain, Aerator, or Circulator. We appreciate you choosing Kasco and for your pur- chase. Your decision to purchase Kasco’s 50Hz Fountain, Aerator, or Circulator will not disap- point you.
  • Page 3 USE AND OPERATION Kasco units are designed and engineered for continuous duty, such as on fish farms or other aquacul- ture applications, or on-demand use, as needed in a recreational water feature.
  • Page 4 ASSEMBLY INSTRUCTIONS FOR 50Hz QUICK DISCONNECT Important – Read Carefully Before Installation Before using the connector, it is important that these instructions are carefully read and understood to en- sure the connector system is completely water tight Stepped Edge and electrically safe. IF IN DOUBT CONSULT A QUALIFIED ELEC- STEP THREE TRICIAN.
  • Page 5 Strain Relief should be installed on the user supplied cord Once the two subassemblies have been completed, length (not on the Kasco supplied stub cord). It should be they can be joined together. Plug pin assembly into position about 15cm from the Quick Disconnect. To in-...
  • Page 6 EVFX & 2400EJF FOUNTAIN PARTS INCLUDED (F2400EVFX, F3400EVFX, & F2400EJF) A. EV or EJ Aerating Fountain (Unit with cord or stub cord) (1) B. Float (with two 50’ mooring ropes attached) (1) A. 1/4-20 x 3 1/4” Phillips Pan Head Screw (4) B.
  • Page 7 2400EJF NOZZLE OPTIONS & PATTERN SIZES NOTE: Pattern sizes listed are approximate. Variations in voltage caused by regional electrical differences or voltage drop due to long power cords may result in reduced pattern sizes. • All five nozzles are included with the 2400EJF package. •...
  • Page 8 Tighten until snug with a Phillips Head screw driver page 6. Make sure you have all the parts needed. If and repeat for 3 remaining screws. any shortages are found, contact your Kasco repre- sentative immediately. STEP TWO Set motor housing upright (stainless steel can down) on a flat surface.
  • Page 9 Pictures corre- spond with Step Five from previ- ous page STEP SIX Turn the assembly upright again. At this time, if the cord contains a metal strain relief, you can use the chain connector and attach it in one of the opening at the rope placement.
  • Page 10 8400EJF & 3.1EJF FOUNTAIN PARTS INCLUDED A. Aerating Fountain (Unit with stub cord) (1) B. Float in separate box (1) (Diagram to Right) 1. Float Section (3) 2. Top Float Bracket (3) 3. Bottom Float Bracket w/ 50’ rope (3) 4.
  • Page 11 8400EJF and 3.1EJF NOZZLE OPTIONS & PATTERN SIZES NOTE: Pattern sizes listed are approximate. Variations in voltage caused by regional electrical differences or voltage drop due to long power cords may result in reduced pattern sizes. • The Linden, Willow, and Juniper nozzles use the 3/8” x 4” bolt. •...
  • Page 12 Parts Included sheet in this manual on top and bottom brackets using three 1/4” x 3/4” Bolts page 9. Make sure you have all the parts needed. If (Part B7) with any shortages are found, contact your Kasco repre- the three 1/4” sentative immediately. Lock Washers...
  • Page 13 To install the Redwood nozzle, make sure the Y In- sert (Part D4) is installed and seated properly into the nozzle. Push the nozzle down over the cone assem- bly (it may require light taps with a rubber mallet to seat properly).
  • Page 14 Aerator Parts Included (EAF Models) A. Aerator (Unit with cord or stub cord) (1) B1. Small Float Ring with two 50’ mooring ropes attached (For F2400 and F3400 Models) (1) B2. Large Float Ring (For 8400 Model) See Diagram 1. Float Section (3) 2.
  • Page 15: Eaf Assembly Instructions

    Next, cross reference the parts included in the ship- ment with the Parts Included sheet in this manual on page 13. Make sure you have all the parts needed. If any shortages are found, contact your Kasco repre- sentative immediately. FOR F2400 & F3400 MODELS (SMALL FLOAT) STEP TWO Slide the two 50’...
  • Page 16 STEP THREE For Model 8400EAF, the notch in the center of the Position one Top Float Bracket (Part B2-2)so the bolt Unit Mounting Bracket should be positioned over the holes in the bracket align with the bolt holes in the top ring of the cage and should be attached to the two adjoined float sections and insert two 9”...
  • Page 17: Evfx, Ejf, & Eaf Installation Instructions

    STEP THREE At this time the Fountain or Aerator is ready for operation. It can be plugged into the power supply at the pond edge. ENJOY YOUR NEW KASCO EQUIPMENT!
  • Page 18: Ecf Assembly & Installation Instructions

    Next, cross reference the parts included in the ship- ment with the Parts Included sheet in this manual on page 13. Make sure you have all the parts needed. If any shortages are found, contact your Kasco repre- sentative immediately. STEP TWO Models 2400 &...
  • Page 19 STEP SEVEN Insert the Spacer Bracket (Part B7)under the U- Bracket and inside the cage. Secure this assembly using one 1/4” x 1” Bolt (Part B9) and a 1/4” Lock Step Nine Nut (Part B11), and one 1/4” x 1-1/4” Bolt (Part B10) and a 1/4”...
  • Page 20 Sink weight behind the unit so rope is taught. At this time take up any slack in the line. STEP FOURTEEN You can now plug the Circulator into the GFI pro- tected power source at the ponds edge. ENJOY YOUR NEW KASCO CIRCULATOR!
  • Page 21: Maintenance Recommendations

    Storage over winter is best in a location that is out of the sun and cool, but above 32 F. It is not necessary to store Kasco motors upside down. All internal seals are fully lubricated while stored in an upright position.
  • Page 22: Troubleshooting Tips

    Kasco distributor or representative for further steps. “My Kasco Equipment hums, but will not start. When I spin the prop with a stick, it starts up.” This indicated a problem with the Starting Capacitor. Each Kasco unit is equipped with a Starting Capacitor to get the unit going when it is first plugged in.
  • Page 23 Kasco Marine, Inc. 800 Deere Rd. Prescott, WI 54021 Phone (715) 262-4488 * Fax (715) 262-4487 www.kascomarine.com * sales@kascomarine.com * service@kascomarine.com 884150...