MOVING WATER FORWARD, SINCE 1968 EJ SERIES FOUNTAIN 4400EJ, 8400EJ, 2.3EHJ, 3.1EHJ, 3.3EHJ Operation & Maintenance Manual Document number 884156 Document version 2022.1.0 800 Deere Rd. Prescott, WI 54021 | sales@kascomarine.com | kascomarine.com MID-SIZE EJ SERIES FOUNTAIN MANUAL...
(3) Anchors or stakes for installing unit • 9/16’’ socket with extension and ratchet (optional) • 7/16’’ socket and ratchet or combination wrench (optional) • (3) 12’’ pieces of 1’’ galvanized pipe for weighting ropes (optional) MID-SIZE EJ SERIES FOUNTAIN MANUAL...
10.1m Mahogany (841345) Mighty Oak (841335) 841250 Height Width Height Width 3.2m 9.1m 3.4m 10.4m 13.4m 14.6m 5.9m 17.1m 5.9m 17.1m 841250 841250 Contact Kasco Marine at sales@kascomarine.com or your local distributor for order information. MID-SIZE EJ SERIES FOUNTAIN MANUAL...
Page 7
ASSEMBLY INSTRUCTIONS Dedicated power cord channel Repeat. MID-SIZE EJ SERIES FOUNTAIN MANUAL...
Page 8
ASSEMBLY INSTRUCTIONS (CONT.) Fasten loosely. Dedicated power cord channel MID-SIZE EJ SERIES FOUNTAIN MANUAL...
Page 9
If your Kasco cord comes with a strain relief kit at- tached, attach the available link to the float-side knot in the mooring rope, as pictured here.
Page 10
NOZZLE INSTALLATION INSTRUCTIONS Twist until snug Do not over-tighten. For Linden/Balsam Nozzles: Balsam Linden OUTLET (6) nozzle installed MID-SIZE EJ SERIES FOUNTAIN MANUAL...
(at least 3 feet from the float for every foot of water depth). Alternate Installation Anchor rope Secondary weight Normal water level Low water level High water level MID-SIZE EJ SERIES FOUNTAIN MANUAL...
If unit is connected to a circuit protected by a fuse, use a time-delay fuse with this pump. You must verify motor rotation before installing the unit in the water. 3-phase Kasco units will run in a clockwise rotation when looking down at the propeller. Keep clear of the propeller while verifying rotation.
Sacrificial Anode All Kasco units include a sacrificial anode installed on the shaft to protect against corrosion and electrolysis. Replace the anode if it is reduced to half the original size or if it is white in color. Corrosion from electrolysis most commonly occurs in saltwater or brackish water, but it is important to check the anode in all installations at least every two to three months.
Turn the unit off and disconnect from power source. • Remove the equipment from the water and inspect for debris or damage. • If there is build-up on the unit and motor can, remove the debris and clean the unit. MID-SIZE EJ SERIES FOUNTAIN MANUAL...
Also, register the unit online at: www.kascomarine.com. Once the warranty coverage has been established, the unit may be sent to any Kasco authorized repair center for evaluation and repair. Please call Kasco at 715-262-4488 prior to shipping to receive any updated information or a repair form, or call to locate your nearest authorized repair center.
Please ship according to the instructions in the previous section. Kasco does estimates on repairs at the request of the customer. The request for an estimate should be included in the letter that accompanies the returned unit and must include a daytime phone number and/or email address.
REPAIR CONTACT FORM • Kasco requires that all equipment sent for repair MUST be accompanied by this form and marked to Repairs attention. Kasco Marine • Unit should be cleaned before shipping. 800 Deere Road • Kasco is NOT responsible for shipping damage accrued in Prescott, WI 54021 return shipment.