STEP SIX
Slide the gland and gland nut along the cable into the
body and tighten the gland nut securely.
STEP SEVEN
Once the two subassemblies have been completed,
they can be joined together. Plug pin assembly into
the socket assembly and tighten the large blue nut se-
curely. The blue nut should be hand tightened only.
(See figure below).
Note: There is a small gap after tightening
KASCO MARINE 50Hz WIRE SIZING AND
QUICK DISCONNECT GLAND SIZING CHARTS
The chart below has recommend cord length and the
associated wire size/gauge to supply proper voltage to
each Kasco 50Hz unit. Kasco does not recommend
adding more than 60m of cord to any unit.
Kasco Marine 50Hz Equipment Wire
Size Chart
Model
10m
F2400EAF
1.5mm
F2400ECF
1.5mm
F2400EVFX 1.5mm
F3400EAF
1.5mm
F3400ECF
1.5mm
F3400EVFX 1.5mm
8400EAF
1.5mm
8400ECF
1.5mm
8400EJF
1.5mm
3.1EJF
1.5mm
Cord Length
30m
60m
2
2
2
1.5mm
4mm
2
2
2
1.5mm
4mm
2
2
2
1.5mm
4mm
2
2
2
1.5mm
4mm
2
2
2
1.5mm
4mm
2
2
2
1.5mm
4mm
2
2
2
4mm
4mm
2
2
2
4mm
4mm
2
2
2
4mm
4mm
2
2
2
4mm
6mm
For seasonal removal, your quick disconnect includes
an optional water tight cover. Simply separate the
quick disconnect and insert the sealing cover into the
large blue nut half and tighten firmly.
Strain Relief
The Strain Relief must be installed to protect the Quick
Disconnect from damage due to excessive strain. The
Strain Relief should be installed on the user supplied cord
length (not on the Kasco supplied stub cord). It should be
position about 15cm from the Quick Disconnect. To in-
stall, insert the narrow end of the elongated clamp with the
chain connected into the wide end of the short clamp.
Use a rubber mallet to tap the two pieces together se-
curely. A Nylon Tie can be used to keep in attached to the
cord. The chain can then be attached to the float.
The chart below shows the proper Gland to be used
with different cord sizes. The measurements are
based on the Outside Diameter (O.D.) of the cord.
Smooth, round cords should be used.
Kasco Marine Quick Disconnect
50Hz Gland Size Chart
Gland
O.D. of Cord
Grey
7-9mm
White
9-11mm
Yellow
13-15mm
5