Turn on the power source.
Turn on the power switch of the access controller.

Checks after powering on the access controller (recommended)

After powering on the access controller, check that:
The cooling system works normally. You should be able to hear the fans working and feel air
flowing from the air exhaust.
The LEDs on the switch interface board panel work normally.
Table 24
describes the status of the LEDs on the switch interface board upon access controller power-on.
Table 24 Switch interface board LED status upon access controller power-on
Step
1
2
3
4
The system LEDs on the main control board panel work normally.
Table 25
describes the status of the LEDs on the main control board upon access controller power-on.
Table 25 Description of main control board LED status upon access controller power-on
Step
1
2

Boot process

During the access controller power-on process, the console terminal connected with the access controller
displays the following information:
NOTE:
The following output may vary with main control board models and software versions. The
EWPX1WCMB0 is used as an example unless otherwise specified.
System start booting...
Booting Normal Extend BootWare....
LED status
The four optical combo port LEDs (yellow) become steady on.
The optical combo LEDs go off.
The 10GE interface module LED (green) becomes steady on (with an interface module in place).
All the LEDs go into normal indication status.
For more information, see the chapter "Access controller overview."
LED status
All the LEDs on the front panel blink once.
All the LEDs go into normal indication status.
For more information, see the chapter "Access controller overview."