Figure 53 Download the file using Xmodem
Upon successful download, the system displays the following information:
Download successfully!
354944 bytes downloaded!
Updating Basic BootWare? [Y/N]Y
Updating Basic BootWare................Done!
Updating Extend BootWare? [Y/N]Y
Updating Extend BootWare..............Done!
Change the baud rate on the console terminal from 1 15,200 bps back to 9,600 bps, and reboot the
Step9
access controller.
NOTE:
The actual file name, size and path may differ from what are shown in the figure above. Before
upgrading the software of your access controller, check the current BootWare version and application
program version to make sure that the correct file is used for the upgrade.
After you download files with a changed baud rate, timely change the baud rate back to 9,600 bps in
HyperTerminal to ensure the normal display on the console screen when the system boots or reboots.
Upgrading applications through a serial
connection
The procedure is used to upgrade the three types of application files. This section describes how to
upgrade the main application file.
Follow these steps to upgrade the main application file:
Select 2 in the BootWare main menu to enter the serial interface submenu. For more information about
Step1
this menu, see
"BootWare
submenus."