Upgrading Applications Through An Ethernet Interface; Configuring Ethernet Interface Parameters - H3C WX6103 Installation Manual

Hide thumbs Also See for WX6103:
Table of Contents

Advertisement

To improve the upgrading speed, first modify the serial interface baud rate. For more information, see
Step2
"Modifying serial communication
Select 2 in the serial interface submenu. The following prompt appears:
Step3
Please Start To Transfer File, Press <Ctrl+C> To Exit.
Waiting ...CCCCCCCCCC
Select and send the application file in HyperTerminal. The procedure for upgrading an application file
Step4
is the same as upgrading the BootWare. For more information, see
a serial
connection."
NOTE:
The size of an application program is typically over 10 MB. Even at the baud rate of 115,200 bps, the
upgrade takes about 30 minutes. Therefore, you are recommended to upgrade an application program
through an Ethernet interface.
Upgrading applications through an Ethernet
interface
Select 3 in the BootWare main menu to enter the Ethernet interface submenu. For more information about
this submenu, see

Configuring Ethernet interface parameters

Before upgrading an application program through an Ethernet interface, configure the Ethernet interface
of the access controller, as follows.
Select 3 in the BootWare main menu to enter the Ethernet interface submenu. Then, select 5 to enter the
Ethernet interface configuration submenu:
============================<ETHERNET PARAMETER SET>============================
|Note:
|
|
================================================================================
Protocol (FTP or TFTP) :tftp
Load File Name
Target File Name
Server IP Address
Local IP Address
Gateway IP Address
NOTE:
When configuring a parameter, you can enter a new value directly, or press Enter to accept the default
value that follows a colon. Type . to clear the current input, - to return to the previous parameter field, and
Ctrl+D to quit from the parameter configuration interface.
The WX6103 access controller supports only the 10/100/1000Base-TX out-of-band management
Ethernet interface for application upgrade.
parameters"
"Ethernet interface
'.' = Clear field.
'-' = Go to previous field.
Ctrl+D = Quit.
:wx6103.bin
:wx6103.bin
:192.168.0.179
:192.168.0.1
:192.168.0.10
submenu."
76
"Upgrading the BootWare through
|
|
|