Item
MDI/MDI-X
Interface speed
Medium and maximum transmission distance
Function
Table 7
describes the status LEDs of the Ethernet interface.
Table 7 Description of the management Ethernet interface status LEDs
LEDs
LINK (green)
ACT (orange)
Console port
The WX6103 provides an RS-232 asynchronous serial console port (CON) using an RJ-45 connector. The
console port can be connected to a computer for system debugging, configuration, maintenance,
management, and host software loading.
Table 8 Technical specifications for the console port
Item
Connector type
Number of interfaces
Interface standard
Baud rate
Transmission distance
Functions
Reset button
The reset button (RESET) is used to restart the current active main control board.
If the access controller has only one main contro
•
Specification
MDI/MDI-X autosensing
10 Mbps, half duplex/full duplex
100 Mbps, half duplex/full duplex
1000 Mbps, full duplex
Direct-through or crossover Category-5 twisted pair cable,
with a maximum transmission distance of 100 m (328.1 ft)
Host software and Boot ROM upgrade and network
management
Meaning
•
Off—the network cable is not connected.
•
Steady on—the network cable is connected.
•
Off—no data is being transmitted/received.
•
Blinking—data is being transmitted/received.
Specification
RJ-45
1
Asynchronous EIA/TIA-232
9600 bps to 115200 bps
9600 bps by default
≤15 m (49.21 ft)
•
To connect with a character terminal
•
To connect with the serial interface of a local PC
running a terminal emulation program for access
controller configuration
•
Command line interface
8