Table 2 Power supply specifications
Item
Rated voltage range
Maximum input current
Maximum power for a
single power supply
Dimensions (H × W × D)
Power supply slot
System power
consumption range
Hot swapping
Redundancy
LED
WARNING!
Figure 3 Front panel of the PSR650-A
1 2 3 4 1 :3
Description
PSR650-A: 100 VAC to 240 VAC; 50 or 60 Hz
PSR650-D: –48 VDC to –60 VDC
PSR650-A: 10 A
PSR650-D: 25 A
650 W
40 × 165 × 350 mm (1.57 × 6.50 × 13.78 in)
Two slots, and AC and DC power supplies cannot be inserted in the same slot at
the same time.
EWPX1WCMB0 main control board:
104 W to 233 W
Supported
NOTE:
Hot swapping means to power turn off the power switch before and then unplug a
PSU when the access controller has multiple PSUs while, without interrupting
ensuring the normal operation of the access controller; check that the power switch
is off before plugging a PSU, and then power turn on the power switch.
Supported
There is a power status LED above the power supply switch. Green means the
power supply operates properly, and red means the power supply is faulty.
The WX6103 supports both AC power input and DC power input. You can use AC or DC PSUs as
needed. Different types of PSUs cannot be used on the same WX6103 access controller.
The minimum system power consumption described in
board is installed and the switch interface board runs with no load. The maximum system power
consumption is obtained when two main control boards are installed and the switch interface board
runs with full load.
EWPX1WCMD0 main control board:
136 W to 309 W