Enter your choice(0-5):
NOTE:
After downloading files with a changed baud rate, timely change the baud rate back to 9,600 bps in
HyperTerminal to ensure the normal display on the console screen when the system boots or reboots.
Upgrading the BootWare through the management Ethernet
interface
Follow these steps to upgrade the BootWare through the management Ethernet interface:
Enter the BootWare main menu (see
Step1
submenu. For more information about this menu, see
Select 4 in the BootWare operation submenu to enter the BootWare operation Ethernet interface
Step2
submenu:
=====================<BOOTWARE OPERATION ETHERNET SUB-MENU>=====================
|<1> Update Full BootWare
|<2> Update Extend BootWare
|<3> Update Basic BootWare
|<4> Modify Ethernet Parameter
|<0> Exit To Main Menu
================================================================================
Enter your choice(0-4):
Select 4 in the BootWare operation Ethernet interface submenu. The system prompts you to modify the
Step3
network parameters.
============================<ETHERNET PARAMETER SET>============================
|Note:
|
|
================================================================================
Protocol (FTP or TFTP) :tftp
Load File Name
Target File Name
Server IP Address
Local IP Address
Gateway IP Address
NOTE:
The load file name and target file name must not exceed 50 bytes.
When configuring a parameter, you can enter a new value directly, or press Enter to accept the default
value that follows a colon. Type . to clear the current input, - to return to the previous parameter field, and
Ctrl+D to quit from the pareter configuration interface.
The WX6103 access controller supports only the 10/100/1000Base-TX out-ofd management
Ethernet interface for application upgrade.
After modification of the parmeters, the system display returns to the BootWre operon Ethernet
interface submenu.
'.' = Clear field.
'-' = Go to previous field.
Ctrl+D = Quit.
:wx6103.bin
:wx6103.bin
:192.168.0.179
:192.168.0.125
:192.168.0.1
"BootWare
menus.") and select 7 to enter the BootWare operation
"BootWare operation
71
submenu."
|
|
|
|
|
|
|
|