H3C WX6103 Installation Manual page 29

Hide thumbs Also See for WX6103:
Table of Contents

Advertisement

Mounting the access controller on a workbench
Follow these steps to mount the access controller on a workbench:
Before placing the access controller on a workbench, confirm the following preparations:
Step1
The workbench is sturdy enough to support the weight of the access controller and its accessories.
There are no obstacles on and around the workbench.
Move the access controller to the front of the workbench.
Place the access controller on the top of the table.
Step2
Connecting the grounding cable
WARNING!
For the safety of operators and equipment, securely ground the access controller.
Most cabinets are equipped with a grounding strip. You can connect the grounding wire (yellow-green
PGND cable) of the access controller to the grounding strip.
Follow these steps to connect the PGND cable:
Remove the grounding screw at the back of the chassis.
Step1
Put the supplied OT terminal of the PGND cable on the grounding screw.
Step2
Insert the grounding screw into the grounding hole and screw it down.
Step3
Connect the other end of the PGND cable to the grounding strip of the cabinet.
Step4
Secure the grounding cable on the grounding strip with a nut.
Step5