Phocos Any-Grid Series User And Installation Manual page 28

Pure sine wave hybrid inverter charger with mppt solar charge controller
Hide thumbs Also See for Any-Grid Series:
Table of Contents

Advertisement

Battery type
Settings menus 26, 27 and 29
can only be modified if "User-
defined" is selected here.
Please visit www.phocos.com
for a current list of (Lithium)
batteries supported and their
05
specific settings guides.
CAUTION: Do not use
inverter communication
cables supplied with your
batteries unless instructed
by Phocos guides as this
may damage the PSW-H
and/or the battery!
Automatic restart if an AC
06
output overload occurs
Automatic restart when over-
07
temperature occurs
www.phocos.com
UPS (Default)
AGM (Default)
User-defined
Pylontech battery
WeCo battery
BYD battery
RS-485 (MODBUS RTU) battery
Restart disabled (Default)
Restart disabled (Default)
Accepted AC input voltage range
from 170 ~ 280 Vac for 230 Vac
models, 90 ~ 140 Vac for 120 Vac
models.
Flooded
Battery charging voltages and low
voltage disconnect (LVD) can be
manually defined in settings menu
26, 27 and 29.
For use with Pylontech Lithium
batteries. Ensure the battery
management system (BMS)
communication is connected.
For use withWeCo Lithium
batteries. Ensure the battery
management system (BMS)
communication is connected.
For use with BYD Lithium batteries.
Ensure the battery management
system (BMS) communication is
connected.
For use with Lithium batteries
using the Phocos MODBUS RTU
communication protocol. Ensure
the battery management system
(BMS) communication is
connected.
Restart enabled
Restart enabled
27 |
P a g e