Program example
(1) Program used at head of circuit block.
M32
10
M32
12
(2) Program used at head of circuit block connected with ANB.
X0
99
ANB
(3) Program used at head of circuit block connected with ORB.
X8
M1
93
X12
M60
Circuit block
connected with ORB.
M9
M13
M35
Circuit block
connected with ANB.
ORB
- 39 -
Coding
No. of
Y10
steps
10
Y11
11
12
13
14
Coding
No. of
Y99
steps
99
100
101
102
103
104
105
Coding
No. of
M99
steps
93
94
95
96
97
98
99
LD, LDI
Com-
Device
mand
LD
M32
OUT
Y10
LDI
M32
OUT
Y11
Com-
Device
mand
LD
X0
LD
M9
AND
M13
ORI
M35
ANB
OUT
Y99
Com-
Device
mand
LD
X8
AND
M1
LD
X12
ANI
M60
ORB
OUT
M99