Mitsubishi Electric MELDAS 60 Series Programming Manual page 210

Plc programming
Hide thumbs Also See for MELDAS 60 Series:
Table of Contents

Advertisement

(11) Automatic tool data write
All tool Nos. are written (entered) in batch. This command is used for initialization, etc.
The data are written one after another for each tool, starting from the default value.
ACT
R500
540
R501
R540
1000
R2965
2
R3000
1008 (0)
R3001
1009 (1)
R3002
1000 (2)
1001 (3)
1002 (4)
1003 (5)
1004 (6)
1005 (7)
R3009
1006 (8)
R3010
1007 (9)
S.ATC K11
R500
R2960
M10
Register No. where default value is stored
Default value
Pointer
Tool data table head
Tool data of the number of tools are written
while incrementing the default value indicated
by pointer by one.
(Note) When pointer is not used, R2965 should be
set to "zero".
Ex.)
- 202 -
9. Exclusive Commands
MOV K0 R2965