Mitsubishi Electric MELDAS 60 Series Programming Manual page 52

Plc programming
Hide thumbs Also See for MELDAS 60 Series:
Table of Contents

Advertisement

ANB ... Serial connection of circuit block
Bit device
X
Y
M
L SM F
Function
(1) AND operation of the A block and B block is executed, and the operation results are obtained.
(2) The ANB symbol is a connection symbol instead of a contact symbol.
(3) When consecutively writing ANB, a max. of 7 commands (8 blocks) can be written. The PC
cannot execute a correct operation if 8 or more commands are written consecutively.
Usable device
Word device
T
C
D
R
Z
ANB
A block
B block
Con-
Pointer
Level
stant
K
H
P
- 44 -
ANB
Digit
No. of
desig-
Index
steps
nation
N
1

Hide quick links: