(2) When a digit is designated on the destination (D) side, the No. of points designated by the digit
will be the target of the destination side.
Circuit side
When source data (S) is a value
When source data (S) is a bit device
When source data (S) is a word device
(Note) The display of the circuit having a digit designation will be as follows.
MOV H1234 K2M0
Destination (D) side
(Note)
MOV K1M0 K2M100
Destination (D) side
MOV
D0 K2M100
Destination (D) side
- 36 -
6. Explanation of Commands
Process
1
2
H1234 0 0 0 1 0 0
M15‥‥‥‥‥‥‥‥M8 M7‥‥‥‥‥‥‥‥M0
K2M0
Does not change
M15 ‥‥‥‥‥‥
M8 M7
1 1 1 0 1 0 1 0 1 0 0 1 1 1 0 1
K1M0
M115 ‥‥‥‥‥‥‥‥‥ M108M107‥‥‥M104M103 ‥‥M100
K2M100
Does not change
0 is transmitted
B15 ‥‥‥‥‥‥‥‥ B8 B7‥‥‥‥‥‥‥B0
D0 1 1 1 0 1 0
M115 ‥‥‥‥‥‥‥‥‥ M108M107‥‥‥‥‥‥‥‥‥‥M100
K2M100
Does not change
K1
K2
MOV
M0
M100
3
4
1 0 0 0 1 1
0
1
0 0
0 0 1 1
0
1
0 0
3
4
‥‥‥‥‥‥‥M0
0 0 0 0 1 1 0 1
The M3 to M0 data
is transmitted
1 0 1 0 0 1
1
1
0 1
1 0 0 1
1
1
0 1