Mitsubishi Electric MELDAS 60 Series Programming Manual page 108

Plc programming
Hide thumbs Also See for MELDAS 60 Series:
Table of Contents

Advertisement

DINC ... (32-bit BIN data) +1
Bit device
X
Y
M
L SM F
D
DINC
Function
(1) The device (32-bit data) designated with D is incremented by one.
D+1
B31 ... ... ... B16 B15 ... ... ... B0
73500 (BIN)
(2) If DINC is executed when the details of the device designated with D are 2147483647,
-2147483648 will be stored in the device designated with D.
Execution conditions
The execution conditions for the DINC command are as shown below.
DINC command OFF
DINC
Usable device
Word device
T
C
D
R
Z
DINC command
DINC
D
+1
ON
Executed per scan
- 100 -
Con-
desig-
Pointer
Level
stant
nation
K
H
P
N
Setting data
Head No. of device to be
D
D
DINCed (+1)
D+1
B31 ... ... ... B16 B15 ... ... ... B0
73501 (BIN)
Executed per scan
DINC
Digit
No. of
steps Index
2
D

Hide quick links: