– Unclip the actuator rod -1- from the ball head vacuum actuator
-2-.
– Remove the vacuum hose -3-, and remove the vacuum ac‐
tuator.
Installing
Install in reverse order of removal and note the following:
The shaft for the intake manifold flaps and the bracket on the In‐
take Manifold Runner Position Sensor 2 - G512- are rectangular.
When installing pay attention that the bracket on the Intake
Manifold Runner Position Sensor - G336- is positioned per‐
pendicular on the shaft for the intake manifold flaps on the
intake manifold flaps.
Note
Replace seals.
Secure all hose connections with standard production hose
clamps. Refer to the Parts Catalog.
– Install the engine cover. Refer to
⇒ "3.4 Engine Covers, Removing and Installing", page 27
– Check the coolant level. Refer to ⇒ Fuel Injection and Ignition;
Rep. Gr. 19 ; Cooling System, Coolant, Draining and Filling .
Tightening Specifications
♦ Refer to
⇒ "3.7 Overview - Intake Manifold Lower Section, Fuel Rail and
Fuel Injectors", page 30
♦ Refer to ⇒ Body Exterior; Rep. Gr. 66 ; Noise Insulation;
Overview - Noise Insulation .
Fuel Injection and Ignition - Edition 02.2015
.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
Audi Q7 2007 ➤
13
2. Vacuum System

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents