– Remove the bolts -2 and 3- and then remove the Intake Mani‐
fold Runner Position Sensor - G336- .
– Unclip the actuator rod -2- from the ball head vacuum actuator.
– Remove the vacuum hose -1-, and remove the vacuum ac‐
tuator.
Installing
Install in reverse order of removal and note the following:
The shaft for the intake manifold flaps and the bracket on the In‐
take Manifold Runner Position Sensor 2 - G512- are rectangular.
When installing pay attention that the bracket on the Intake
Manifold Runner Position Sensor - G336- is positioned per‐
pendicular on the shaft for the intake manifold flaps on the
intake manifold flaps.
Note
Replace seals.
Secure all hose connections with standard production hose
clamps. Refer to the Parts Catalog.
– Install the engine cover. Refer to
⇒ "3.4 Engine Covers, Removing and Installing", page 27
Tightening Specifications
♦ Refer to
⇒ "3.7 Overview - Intake Manifold Lower Section, Fuel Rail and
Fuel Injectors", page 30
2.3.2
Intake Flap Control Vacuum Actuator,
Removing and Installing, Cylinder Bank
2 (Left)
Special tools and workshop equipment required
♦ Hose Clamps - Up To 25mm - 3094-
♦ Hose Clip Pliers - VAS6362-
10
Rep. Gr.24 - Multiport Fuel Injection
.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents