Scb-02 Expansion Pcb Parameters - REMEHA Gas 210 Ace 80 Service Manual

High-efficiency standing gas boiler
Hide thumbs Also See for Gas 210 Ace 80:
Table of Contents

Advertisement

Tab.26
Factory settings at installer level
Code
Display text
EP018
Status relay func. Status relay function
EP019
Status relay func. Status relay function
EP028
Function 10V-
PWM
EP029
Source 10V-PWM Selects the source signal for the 0-10
6.3.3

SCB-02 expansion PCB parameters

Tab.27
Navigation for basic installer level
Level
Menu path
Basic installer
General
(1) See the column "Submenu" in the following table for the correct navigation. The parameters are grouped in specific functionalities.
7837115 - v.01 - 10012023
Description
Selects the function of the 0-10 Volt
output
Volt output
> Installation Setup > SCB-02 > Submenu
Adjustment range
0 = No Action
1 = Alarm
2 = Alarm Inverted
3 = Generator on
4 = Generator off
5 = Reserved
6 = Reserved
7 = Service request
8 = Generator on CH
9 = Generator on DHW
10 = CH pump on
11 = Locking or Blocking
12 = Cooling mode
0 = No Action
1 = Alarm
2 = Alarm Inverted
3 = Generator on
4 = Generator off
5 = Reserved
6 = Reserved
7 = Service request
8 = Generator on CH
9 = Generator on DHW
10 = CH pump on
11 = Locking or Blocking
12 = Cooling mode
0 = 0-10V 1 (Wilo)
1 = 0-10V 2 (Gr GENI)
2 = PWM signal (Solar)
3 = 0-10V 1 limited
4 = 0-10V 2 limited
5 = PWM signal limited
6 = PWM signal (UPMXL)
0 = PWM
1 = Requested power
2 = Actual power
All tables show the factory setting for the parameters.
Important
The tables also list parameters that are only applicable if the boiler
is combined with other equipment.
> Parameters, counters, signals > Parameters >
(1)
6 Settings
Submenu
Default
setting
Status infor­
No Ac­
mation
tion
Status infor­
No Ac­
mation
tion
0-10 volt or
0-10V 1
PWM out
(Wilo)
0-10 volt or
PWM
PWM out
33