Scb-01 Expansion Pcb Parameters; List Of Measured Values; Cu-Gh08 Control Unit Counters - REMEHA Quinta Ace 30 Service Manual

High-efficiency wall-hung gas boiler
Hide thumbs Also See for Quinta Ace 30:
Table of Contents

Advertisement

Code
Display text
Description
PP014
ChPumpD­
Reduction of temperature
TReduction
delta modulating for pump
modulation
PP016
Max. CH
Maximum central heating
pump speed
pump speed (%)
PP017
ChPump­
Maximum central heating
SpeedMax­
at minimum load as per­
Factor
centage of max pump
speed
PP018
Min CH
Minimum central heating
pump speed
pump speed (%)
(1) For the Quinta Ace115, this value is 35°C
6.3.2

SCB-01 expansion PCB parameters

Tab.25
Navigation for installer level
Level
Menu path
Installer
General
(1) See the column "Submenu" in the following table for the correct navigation. The parameters are grouped in specific functionalities.
Tab.26
Factory settings at installer level
Code
Display text
EP028
Function 10V-
PWM
EP029
Source 10V-PWM Selects the source signal for the 0-10
6.4

List of measured values

6.4.1

CU-GH08 control unit counters

Tab.27
Navigation for basic installer level
Level
Menu path
Basic installer
General
(1) See the column "Submenu" in the following table for the correct navigation. The counters are grouped in specific functionalities.
7703943 - v.06 - 13122021
> Installation Setup > SCB-01 > Submenu
Description
Selects the function of the 0-10 Volt
output
Volt output
> Installation Setup > CU-GH08 > Submenu
Adjustment range
Subme­
nu
0 - 40 °C
Gas
fired ap­
pliance
30 - 100 %
Gas
fired ap­
pliance
0 - 100 %
Gas
fired ap­
pliance
30 - 100 %
Gas
fired ap­
pliance
All tables show the factory setting for the parameters.
Important
The tables also list parameters that are only applicable if the boiler
is combined with other equipment.
> Parameters, counters, signals > Parameters >
(1)
Adjustment range
0 = 0-10V 1 (Wilo)
1 = 0-10V 2 (Gr. GENI)
2 = PWM signal (Solar)
3 = 0-10V 1 limited
4 = 0-10V 2 limited
5 = PWM signal limited
6 = PWM signal (UPMXL)
0 = PWM
1 = Requested power
2 = Actual power
> Parameters, counters, signals > Counters >
(1)
30
45
55
65
18
18
18
18
100
100
100
100
100
100
100
100
30
30
30
30
Submenu
0-10 volt or
PWM out
0-10 volt or
PWM out
6 Settings
90
115
18
18
100
100
100
100
30
30
Default
setting
0-10V 1
(Wilo)
PWM
29