Manual NOTCH Width

The relative Manual NOTCH Width can be controlled over a range of 0-127. A
setting of 0 represents lowest Manual NOTCH Width of 10 Hz, and 127 (0x7f) represents
maximum Manual NOTCH Width of 300Hz
The formula is ((315 – 10) / (127 – 1)) * MANNCHWIDTH_Selected Hz
Format:
Where:
Example:

Internal Keyer Speed

The Internal Keyer Speed can be controlled with a range of 5..63wpm. The data
range is 0..127, meaning that the value sent is Desired_Speed * 127/63. Setting the
Desired_Speed to 0 through 4 is ignored in the OMNI-VII and limited to 5wpm.
Format:
Where:
Example1:
Example2:
Example3:
Example4:
Rev 1.009
OMNI-VII Firmware Updates at www.rfsquared.com
'*' 'C2J' <d0> <CR>
'*' = the ASCII '*' symbol (0x2a)
C2J = the ASCII 'C2J' characters (<0x43><0x32><0x4A>)
<d0> = 7 bit MANNCHWIDTH _Selected selection (0x00 to 0x7f)
*C2J<0x00><CR> sets Manual Notch Width to 10Hz
'*' 'C2L' <d0> <CR>
'*' = the ASCII '*' symbol (0x2a)
C2L = the ASCII 'C2L' characters (<0x43><0x32><0x4C>)
<d0> = 7 bit character Desired_Speed
*C2L<0x0a><CR> sets Desired_Speed to 5 wpm.
*C2L<0x32><CR> sets Desired_Speed to 25 wpm.
*C2L<0x64><CR> sets Desired_Speed to 50 wpm.
*C2L<0x7f><CR> sets Desired_Speed to 63 wpm.