Cw Keyer Mode; Cw Keyer Weighting - Ten-Tec OMNI-VII 588 Programmer's Reference Manual

Table of Contents

Advertisement

CW Keyer Mode

This controls whether the OMNI-VII internal keyer mode operates in Mode A or
Mode B mode, or OFF
Format:
Where:
Example1:
Example2:

CW Keyer Weighting

The relative CW Keyer Weighting can be controlled over a range of 0-127. A
setting of 0 represents lowest CW Keyer Weighting Time, and 127 (0x7f) represents
maximum CW Keyer Weighting Time. For firmware version 1.022 onwards, this
represents weighting of 0 to 50%. Prior firmware versions this was 0 to 24%.
Format:
Where:
Example:
Rev 1.009
OMNI-VII Firmware Updates at www.rfsquared.com
'*' 'C2F' <d0> <CR>
'*' = the ASCII '*' symbol (0x2a)
C2F = the ASCII 'C2F' characters (<0x43><0x32><0x56>)
<d0> b0 = Curtis Mode A
b1 = Curtis Mode B
b2 = Internal Keyer ON/Off
*C2F<0x01><CR> Sets to Curtis Mode A, Internal Keyer OFF
This is legal, means that the internal keyer mode is off, but if
changed to
*C2F<0x06><CR> Sets to Curtis Mode B, Internal Keyer ON
'*' 'C2G' <d0> <CR>
'*' = the ASCII '*' symbol (0x2a)
C2G = the ASCII 'C2G' characters (<0x43><0x32><0x47>)
<d0> = 7 bit CW Keyer Weighting selection (0x00 to 0x7f)
*C2G<0x7f><CR> sets CW Keyer Weighting to decimal 63
(50%)
OMNI-VII Programmer's Reference Guide
46 of 63