Contents
Rotate Speed
Control method
VR1
TS1
LED1
LED2
LED3
LED4
LED5
LED6
LED7
3.1.2.

Error release method

When an error occurs, LED1, LED5 and LED6 will light up depending on the content and the motor stop. The
error condition is released by turning VR1 counterclockwise to the end. Also, the contents of the error can be
confirmed by connecting ICS and monitoring the corresponding global variable.
3.1.3.

End of operation

Stop the motor by turning VR1 counterclockwise to the end. After confirming that the motor has stopped, turn off
the power.
R18UZ0078EJ0100 Rev.1.0
Mar 24, 2021
Table 3-1. the initial firmware specification
1200-3900[rpm]
Hall sensor 120° conduction control
Clockwise: Rotation start → acceleration
Counterclockwise: Deceleration → Stop rotation
Top (1-2 short): Rotate clockwise
Bottom (2-3 shorts): Turn counterclockwise
Off: Normal operation
On: Error detected
Off: the motor stops
On: the motor is rotating
Off:1500[rpm] or under
On:1500[rpm] or over
Off:3000[rpm] or under
On:3000[rpm] or over
Off: Normal
On: Error detect
Off: Normal
On: Error detect
Off: 5V power supply stopped
On: 5V power supply in progress
Specification