ENCAD NovaJet 800 Series Service Manual page 80

Table of Contents

Advertisement

HEAD HEIGHT
Figure 3-14. Carriage Head Height Tolerance.
1. Remove the lid and the right cover of the printer. See Chapter 5 for
procedures.
2. Obtain the 3 tools (Micrometer Dial Gauge, Test Cartridge, and
Measuring Tip Extender) from the Height Gauge Kit. Obtain the
Head Height Alignment Plate. Assemble the tools as shown in
Figure
3-15.
SPIN HEAD ON
MICROMETER GAUGE
TO FACE BACKWARDS
TIGHTEN SET
SCREWS
ENSURE TIP EXTENDS
BELOW CARTRIDGE
1/4" (6mm)
Figure 3-15. Setting Up Tools from Height Gauge Kit.
NovaJet 800 Series Service Manual
CARTRIDGE
JET PLATE
PLATEN
MICROMETER
DIAL GAUGE
TEST CARTRIDGE
MEASURING
TIP EXTENDER
Maintenance