Figure 5-36. Right Endcap Connector Locations.
Table 5-1. Thermal Dryer PWA Connections.
J1 Fan 1
J2 Fan 2
J3 Element, Left Conn
J4 Power
J5 Power
2. Reconnect the power cord ground to the main body of the Thermal
Dryer.
3. Attach and secure the Right Endcap Assembly. Torque to 15 in-lbs.
4. Attach the data cable to the right side of the Thermal Dryer Assembly.
5. Attach the Thermal Dryer Assembly power cord the to back of the
printer.
NovaJet 800 Series Service Manual
J7
J6
J6 Element, Right Conn
J7 Thermistor
J8 Fuse, on back of PWA
J9 Thermistor
P1 Data cable
Assembly\Disassembly
J9
J3
J1
J2